24V Condenser / Blower Fan for Thermo King V-Series – 78-1186 / 1E01941G02
Let Northline Parts Do the Heavy Lifting for You!
Not sure which part you need? Our team can help you find the right replacement.
Parts Support Hours: Monday–Friday, 8:00 AM–5:00 PM CT
Live Chat: Available 24/7
I reached out for some replacement head bolts and they responded quickly with a few questions and cautionary information and is sending me some bolts. Great customer service! Thanks
Edward H. — Verified customer
Compatible Models
We do our best to list all compatible models. Although this may be the part you need, your exact model may not appear below.
| Application | Models / Details |
|---|---|
| Thermo King V-series | V-090, V-100, V-200, V-300, V-400, V-500 and selected related units when 78-1186 is specified |
| Other catalog applications | Selected C-series / transport-refrigeration packages using the same fan reference |
Product Overview
The fan moves air through the condenser or heat-exchanger section of the refrigeration unit. A seized motor, damaged blade, worn bearings, or weak electrical connection can reduce airflow and contribute to high head pressure, poor cooling performance, cycling problems, or excessive fan noise.
Matched technical data for 78-1186 identifies a roughly 255 mm fan, 24V operation, approximately 4.0A draw and about 1450 m³/h airflow. Cross-reference listings also associate it with SPAL VA11-BP12/C-57A and earlier Thermo King references.
Key Features & Performance
- 24V electric fan assembly for supported Thermo King transport-refrigeration equipment
- Reference numbers include 78-1186 and 1E01941G02
- Matched specifications: approximately 255 mm diameter, 4.0A and 1450 m³/h airflow
- SPAL cross-reference VA11-BP12/C-57A appears in application data
Specifications & Reference Numbers
- Voltage: 24V
- Thermo King references: 78-1186; 1E01941G02; earlier listings include 4118D92G01 / 45-1241
- Approx. diameter: 255 mm
- Approx. current: 4.0 A
- Approx. airflow: 1450 m³/h
Before You Order
Compare voltage, blade diameter, rotation/airflow direction, connector/lead arrangement and mounting points. Thermo King uses multiple visually similar fans across unit generations.
Frequently Asked Questions
Q: Can a weak condenser fan reduce cooling?
A: Yes. Reduced condenser airflow can raise system pressure and lower refrigeration performance, though refrigerant charge and coil condition should also be checked.
Q: Is 78-1376 the same fan?
A: Some catalogs list 78-1376 as interchangeable in related applications, but verify the electrical and physical configuration before substituting.